TRANCEL TML 1210 – TML 1220

Load Cell to ModBus Transmitter

TRANCEL (TML 1210, TML 1220) has been designed to provide a highly reliable and fast, isolated connection between load cell and PLC, through RS-485. It is ideal for fast filling, batch dispensing, and dynamic weighing applications. Benefiting from the highest interference resistance and long-term reliability, problem-free operation is guaranteed in the harshest environments.

Features

  • Fast and Highly Accurate (1/100000)
  • Adjustable Digital Filter
  • RFI/EMI Screened
  • Parametric or Manual Calibration
  • User-friendly
  • Ultra Low Drift vs. Temperature and Time
  • Load Cell Error Detection System
  • High Speed Serial Interface
  • Isolated Power and Serial Port
  • Transient Suppression on RS-485 Line
  • Compact Case with DIN-rail Mounting

Technical Specification

TML1210TML1220
Supply21.6 – 26.4 VDC, < 1W21.6 – 26.4 VDC, < 2W
Isolated Voltage 1.5 KV RMS, <1min
A/D Converter 24-bit Sigma-Delta, Linearity < 0.0015 % FS
External Resolution , MAX 1/100000
Load Cell Excitation 5 VDC, 120mA, 6x350ohm 5 VDC 120mA, 4x350ohm/CH
Digital Filter Update Rate 5 – 200 Hz 1 – 50 Hz
Serial Port RS-485 2-wire, Isolated, ModBus (RTU)
Baud Rates 9600-19200-38400-115200 bps – Dipswitch Configurable
Address Range 1 … 32 – Dipswitch Configurable
Operation Temperature -20o C to +60o C
Case 96 x 96 x 72 mm, IP20

Downloads

TML1210 Manual-EN
TML1220 Manual-EN

Schematic Diagram

نحوه ارتباط ترنسل با PLC از طریق مدباس

Related Applications