TRANCEL

Load Cell to Analog 4-20mA Transmitter  TLA 1310 – TLA 1320

 

TRANCEL (TLA 1310, TLA1320) has been designed to amplify load cell signal to the very accurate 4-20mA analog signal, comprehensible by various industrial instruments, i.e. PLCs. Being a microcontroller-based device, it provides, for the automation system integrators, the most valuable features and functions like digital “Tare” and “manual calibration” that can be easily done by DIP switches.

Features

  • 3-way galvanic isolated
  • Adjustable update rate
  • Digital tare function
  • Manual calibration by 2%FS or 5%FS
  • RFI/EMI screened
  • Load cell error detection system
  • Loop-powered 4-20mA output
  • Transient suppression on analog Line
  • Compact case with DIN-rail mounting

TECHNICAL SPECIFICATIONS TLA 1310 TLA 1320
Manual  TLA 1310 [EN]
TLA 1320 [EN]
Supply 21.6 – 26.4 VDC , < 1W 21.6 – 26.4 VDC , < 2W
Isolated Voltage 1.5 KV RMS, <1min
A/D Converter 24 bit Sigma-Delta
Analog signal Input range ±20mV
Load Cell Excitation 5 VDC 100mA, 6x350ohm 5 VDC 120mA,4x350ohm/CH
Digital Filter Update Rate 5 – 100 Hz 5 – 10 Hz
Analog Output Loop-Powered (3.5 – 21.5 mA)
Current Loop Supply 18 – 36 VDC
D/A Converter 16 bit
Operation Temperature -20o C  to  +60o C
Case 115 x 100 x 23 mm, IP20

Telegram Chanel : MSAElectronics